Item |
Min |
Typ |
Max |
Comment |
|---|---|---|---|---|
|
Control Unit Input Voltage |
14.4V |
24V |
33.6V |
Recommended voltage is >=20v* |
|
Control Unit Input Power |
- |
50W |
100W |
|
|
Control Unit Output Voltage (Port 3,4) |
- |
24V |
- |
LiDAR & INS |
|
Control Unit Output Current (Port 3,4) |
- |
2A |
- |
|
|
Control Unit Output Voltage (Port 5) |
- |
48V |
- |
Network switch - POE IEEE 802.3af/at |
|
Control Unit Output Current (Port 5) |
- |
0.5A |
- |
|
Note: If voltages lower than 20V is used, the source should be able to deliver 5A at the switch-on stage due to handling in-rush current. For voltages over 20V, 3A is adequate.